Omron E5CC PID controller

Omron E5CC PID controller

Omron E5CC temperature controller

Voltage supply
Control output
Signal input type
Frame Size
E5CC-RX2ASM-800
Out-of-Stock
S$153.20

Key features

  • High-contrast, white LCD display visible from large distances and from any angle
  • Easy to set up, and operate intuitively via CX-Thermo without power supply
  • 50 ms sampling period for fast and precise regulation
  • Functions for diagnosis for secure operations *
  • Useful timer and logic operation functions eliminating the need of a PLC
* Alarm for loop break or PV change rate, heater burnout or sensor burnout detection 

Model Control output 1 Supply voltage Event inputs Heater burnout Comm. Aux output
E5CC-RX2ASM-800 Relay output 100-240 VAC - - - 2
E5CC-QX2ASM-800 Voltage output
E5CC-CX2ASM-800 Current output
E5CC-RX2DSM-800 Relay output 24 VAC/DC
E5CC-QX2DSM-800 Voltage output
E5CC-CX2DSM-800 Current output
E5CC-RX2ASM-801 Relay output 100-240 VAC 2 1
E5CC-QX2ASM-801 Voltage output
E5CC-RX2DSM-801 Relay output 24 VAC/DC
E5CC-QX2DSM-801 Voltage output
E5CC-RX2ASM-802 Relay output 100-240 VAC - RS-485
E5CC-QX2ASM-802 Voltage output
E5CC-RX2DSM-802 Relay output 24 VAC/DC
E5CC-QX2DSM-802 Voltage output
E5CC-CX2ASM-804 Current output 100-240VAC 2  
E5CC-CX2DSM-804 Current output 24 VAC/DC  


Raiting

Power Supply Votage A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Sensor input Models with temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Input impedance Current input: 150 ? max., Voltage input: 1 M? min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Control output Relay SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
Voltage Output voltage: 12 VDC ?20% (PNP), max. load current: 21 mA, with short-circuit protection circuit
Current 4 to 20 mA DC/0 to 20 mA DC, load: 500 ? max., resolution: approx. 10,000
Auxillary output No. of output 2
Spec N.O. relay outputs, 250 VAC, Models with 2 outputs: 3 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V
Event input No. of input 2 or 4 (depends on model)
External contact input spec Contact input: ON: 1 kΩ max., OFF: 100 kΩ min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: Approx. 7 mA per contact
Setting method Digital setting using front panel keys
Indication method 11-segment digital display and individual indicators
Character height: PV: 15.2 mm, SV: 7.1 mm
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, 40% AT, 100% AT, MV limiter, input digital filter, self tuning, PV input shift, run/stop, protection functions, extraction of square root, MV change rate limit, temperature status display, moving average of input value, and display brightness setting
Ambient operating temperature -10 to 50 °C (with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature -25 to 65°C (with no condensation or icing)